Features of common extraglottic devices (EGDs)

Features of common extraglottic devices (EGDs)
Device Glottic location Ability to pass OG tube Ability to intubate blindly
LMA Classic Supraglottic (laryngeal mask) No (1st generation EGD) Yes (variable success)[1,2]
LMA ProSeal Supraglottic (laryngeal mask) Yes (2nd generation EGD) No
LMA Supreme Supraglottic (laryngeal mask) Yes (2nd generation EGD) No
LMA Fastrach Supraglottic (laryngeal mask) No (1st generation EGD) Yes (good success)[3-13]
Aura-i Supraglottic (laryngeal mask) No (1st generation EGD) Yes (limited data)
Aura-Gain Supraglottic (laryngeal mask) Yes (2nd generation EGD) Yes (limited data)
Air-Q Supraglottic (laryngeal mask) Yes (only blocker version) Yes (good success)[11-14]
i-Gel Supraglottic (laryngeal mask) Yes (2nd generation EGD) Yes (variable success)[5,6]
Combitube Retroglottic (laryngeal tube) Yes (2nd generation EGD) No
King LT Retroglottic (laryngeal tube) Yes (only LTS version) No
Courtesy of Erik Laurin, MD, and Aaron Bair, MD.

References:
  1. Asai T. Blind tracheal intubation through the laryngeal mask. Can J Anaesth 1996; 43:1275.
  2. Lim SL, Tay DH, Thomas E. A comparison of three types of tracheal tube for use in laryngeal mask assisted blind orotracheal intubation. Anaesthesia 1994; 49:255.
  3. Ferson DZ, Rosenblatt WH, Johansen MJ, et al. Use of the intubating LMA-Fastrach in 254 patients with difficult-to-manage airways. Anesthesiology 2001; 95:1175.
  4. Rich JM. Recognition and management of the difficult airway with special emphasis on the intubating LMA-Fastrach/whistle technique: a brief review with case reports. Proceedings (Baylor University Medical Center) 2005; 18:220.
  5. Halwagi AE, Massicotte N, Lallo A, et al. Tracheal intubation through the I-gel™ supraglottic airway versus the LMA Fastrach™: a randomized controlled trial. Anesth Analg 2012; 114:152.
  6. Sastre JA1, López T, Garzón JC. [Blind tracheal intubation through two supraglottic devices: i-gel versus Fastrach intubating laryngeal mask airway (ILMA)]. Rev Esp Anestesiol Reanim 2012; 59:71.
  7. Shah VR, Bhosale GP, Mehta T, Parikh GP. A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway. Saudi J Anaesth 2014; 8:183.
  8. Kundra P, Sujata N, Ravishankar M. Conventional tracheal tubes for intubation through the intubating laryngeal mask airway. Anesth Analg 2005; 100:284.
  9. Kanazi GE, El-Khatib M, Nasr VG, et al. A comparison of a silicone wire-reinforced tube with the Parker and polyvinyl chloride tubes for tracheal intubation through an intubating laryngeal mask airway in patients with normal airways undergoing general anesthesia. Anesth Analg 2008; 107:994.
  10. Khan MU. Endotracheal intubation in patients with unstable cervical spine using LMA-Fastrach and gum elastic bogie. J Coll Physicians Surg Pak 2014; 24:4.
  11. Erlacher W, Tiefenbrunner H, Kastenbauer T, et al. CobraPLUS and Cookgas air-Q versus Fastrach for blind endotracheal intubation: a randomised controlled trial. Eur J Anaesthesiol 2011; 28:181.
  12. Karim YM, Swanson DE. Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™. Anaesthesia 2011; 66:185.
  13. Yang D, Deng XM, Tong SY, et al. [Roles of Cookgas and Fastrach intubating laryngeal mask airway for anticipated difficult tracheal intubation]. Zhongguo Yi Xue Ke Xue Yuan Xue Bao 2013; 35:207.
  14. Garzón Sánchez JC, López Correa T, Sastre Rincón JA. [Blind tracheal intubation with the air-Q® (ILA-Cookgas) mask. A comparison with the ILMA-Fastrach™ laryngeal intubation mask]. Rev Esp Anestesiol Reanim 2014; 61:190.
Graphic 106515 Version 1.0

آیا می خواهید مدیلیب را به صفحه اصلی خود اضافه کنید؟