ﺑﺎﺯﮔﺸﺖ ﺑﻪ ﺻﻔﺤﻪ ﻗﺒﻠﯽ
خرید پکیج
تعداد آیتم قابل مشاهده باقیمانده : 3 مورد
نسخه الکترونیک
medimedia.ir

Computed tomography studies on detection of cardiac allograft vasculopathy

Computed tomography studies on detection of cardiac allograft vasculopathy
Author, year n Gold standard Sensitivity Specificity
Romeo, 2005[1] 53

Angiography

>50 percent stenosis
0.83 0.95
Iyengar, 2006[2] 20

Angiography

>50 pecent stenosis
1/1 detected
Sigurdsson, 2006[3] 54

Angiography

>50 percent stenosis
0.86 0.99
Gregory, 2006[4] 20 IVUS 0.70 0.92
Pichler, 2008[5] 66

Angiography

>70 percent stenosis
0.59 0.94
Schepis, 2009[6] 30 IVUS 0.85 0.84
Mastrobuoni, 2009[7] 30 Angiography* 0.92
Von Ziegler, 2009[8] 28

Angiography

>50 percent stenosis
0.88 0.97
Von Ziegler, 2012[9] 48

Angiography

>50 percent stenosis
1.00 0.86
Mittal, 2013[10] 138

Angiography

>50 percent stenosis
0.96 0.93
IVUS: intravascular ultrasound; CT: computed tomography.
* Only performed when CT is abnormal.
References:
  1. Romeo G, Houyel L, Angel CY, et al. Coronary stenosis detection by 16-slice computed tomography in heart transplant patients: comparison with conventional angiography and impact on clinical management. J Am Coll Cardiol 2005; 45:1826.
  2. Iyengar S, Feldman DS, Cooke GE, et al. Detection of coronary artery disease in orthotopic heart transplant recipients with 64-detector row computed tomography angiography. J Heart Lung Transplant 2006; 25:1363.
  3. Sigurdsson G, Carrascosa P, Yamani MH, et al. Detection of transplant coronary artery disease using multidetector computed tomography with adaptative multisegment reconstruction. J Am Coll Cardiol 2006; 48:772.
  4. Gregory SA, Ferencik M, Achenbach S, et al. Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy. Am J Cardiol 2006; 98:877.
  5. Pichler P, Loewe C, Roedler S, et al. Detection of high-grade stenoses with multislice computed tomography in heart transplant patients. J Heart Lung Transplant 2008; 27:310.
  6. Schepis T, Achenbach S, Weyand M, et al. Comparison of dual source computed tomography versus intravascular ultrasound for evaluation of coronary arteries at least one year after cardiac transplantation. Am J Cardiol 2009; 104:1351.
  7. Mastrobuoni S, Bastarrika G, Ubilla M, et al. Dual-source CT coronary angiogram in heart transplant recipients in comparison with dobutamine stress echocardiography for detection of cardiac allograft vasculopathy. Transplantation 2009; 87:587.
  8. von Ziegler F, Leber AW, Becker A, et al. Detection of significant coronary artery stenosis with 64-slice computed tomography in heart transplant recipients: a comparative study with conventional coronary angiography. Int J Cardiovasc Imaging 2009; 25:91.
  9. von Ziegler F, Rummler J, Kaczmarek I, et al. Detection of significant coronary artery stenosis with cardiac dual-source computed tomography angiography in heart transplant recipients. Transpl Int 2012; 25:1065.
  10. Mittal T, Panicker M, Mitchell A, et al. Cardiac allograft vasculopathy after heart transplantation: electrocardiographically gated CT angiography for assessment. Radiology 2013; 268:374.
Courtesy of Dr. Finn Gustafsson.
Graphic 54030 Version 7.0