Warming and transport equipment |
- Preheated warmer
- Warm blankets
- Hat
- Plastic bag or wrap (for preterm infants <32 weeks gestation)
- Transport incubator
|
Suction equipment |
- Bulb suction
- Mechanical suction with 10 or 12 French suction catheters and 80 to 100 mmHg wall suction
- Manual suction with 8 French feeding tube and 20 cc syringe
- Meconium aspirator
|
Monitoring equipment |
- Stethoscope for auscultation of the heart and lungs
- Cardiac monitor
- Pulse oximeter monitor with sensor
|
Oxygenation supplementation and ventilation |
- Source for free-flowing oxygen (tanks or wall supply of oxygen and air)
- Oxygen blender (set to 21 to 30% oxygen concentration for neonates <35 weeks gestation; all others 21% oxygen concentration)
- Face masks with appropriate sizing for term and preterm infant
- Positive-pressure device (T-piece resuscitator, flow-inflating bag, or self-inflating bag)
- Oropharyngeal airway
|
Intubation equipment |
- Laryngoscope blades (size 0 and 1), handle, and stylet
- Endotracheal tubes (size 2.5, 3, and 3.5)
- End-tidal carbon dioxide (CO2) detector
- Endotracheal tube securing device or tape
- Laryngeal mask airway
|
Vascular access and equipment to administer |
- Umbilical venous catheterization tray and supplies
- Peripheral intravenous catheters with securing supplies
- Needles
- Syringes
|
Medications |
- Intravenous epinephrine 1 mg/10 mL vial (0.1 mg/mL)
- Normal saline
- 10% dextrose
- Naloxone hydrochloride (0.4 mg/mL)
|