Initial parathyroid surgery: Diagnostic accuracy of preoperative imaging modalities

Initial parathyroid surgery: Diagnostic accuracy of preoperative imaging modalities
Imaging modality Sensitivity (%) Positive predictive value (%)
Sestamibi
Dual-phase planar 41-96  
SPECT or SPECT/CT 67-86 91-96
Ultrasound 76-80 93
4D-CT 62-88 84-90
MRI
1.5T 64-79  
3T 64-98 67-95
PET-CT
18F-fluorocholine 92-95 92-97
11C-methionine 77 98
CT: computed tomography; MRI: magnetic resonance imaging; PET: positron emission tomography; SPECT: sestamibi-single photon emission computed tomography.