ﺑﺎﺯﮔﺸﺖ ﺑﻪ ﺻﻔﺤﻪ ﻗﺒﻠﯽ
خرید پکیج
تعداد آیتم قابل مشاهده باقیمانده : 3 مورد
نسخه الکترونیک
medimedia.ir

Two-dimensional transthoracic echocardiogram (2D TTE) and M mode from the apical 4 chamber view showing TAPSE measurement

Two-dimensional transthoracic echocardiogram (2D TTE) and M mode from the apical 4 chamber view showing TAPSE measurement
Tricuspid annular plane systolic excursion (TAPSE) is measured in the apical four-chamber view by placing an M-mode cursor on the lateral tricuspid annulus and measuring the peak distance travelled by this reference point during systole. A greater distance travelled during systole implies greater right ventricular systolic function, with the normal reference limit being a TAPSE of ≥1.7 cm.
Courtesy of Jonathon Afilalo, MD and Lawrence Rudski, MD.
Graphic 90790 Version 2.0