Journal of Glaucoma




دسترسی یکساله به بیش از ۵۰۰ ژورنال روز جهان موجود در سامانه
    http://medilib.ir
  • ﻣﺪﺕ ﺯﻣﺎﻥ : 365 ﺭﻭﺯ
  • قیمت : 3,800,000 تومان
  • قیمت ویژه : 1,900,000تومان
سفارش

Glaucoma and Telemedicine.

Brandao-de-Resende, Camilo MD, PhD *; Alcantara, Liliane de Abreu Rosa de MD +; Vasconcelos-Santos, Daniel Vitor MD, PhD +; Diniz-Filho, Alberto MD, PhD +

doi : 10.1097/IJG.0000000000002200

Volume 32(5) pgs. 327-441,e38-e42 May 2023

Teleglaucoma is the future, but there is a need for clearer regulation by government agencies and medical entities, as well as for studies to further demonstrate the cost-effectiveness and safety of teleglaucoma strategies at a global scale.

خرید پکیج و مشاهده آنلاین مقاله


Anterior Chamber Washout During Ahmed Valve Glaucoma Surgery Reduces the Incidence of Hypertensive Phase.

Chang, Melissa M. BS *; Yang, Christopher D. BS *; Ly, Huy Q. MD +; Minckler, Donald S. MD, MS +; Lin, Ken Y. MD, PhD *,+,++

doi : 10.1097/IJG.0000000000002215

Intraoperative anterior chamber (AC) washout reduces the odds of hypertensive phase (HP) by 95% compared with those not receiving washout during Ahmed glaucoma implant (AGI), suggesting AC washout is an effective prophylaxis for postoperative HP.

خرید پکیج و مشاهده آنلاین مقاله


Association of Optic Nerve Head and Macular Optical Coherence Tomography Measures With Glaucoma-Related Disability.

Bonham, Luke W. MD *,+; Mihailovic, Aleksandra ScM *,+; Xiao, Grace BA *,+; West, Sheila K. PhD *,+; Friedman, David S. MD, PhD *,+; Ramulu, Pradeep Y. MD, PhD *,+

doi : 10.1097/IJG.0000000000002191

Optical coherence tomography (OCT) estimated retinal nerve fiber layer (RNFL) thickness associated with glaucoma-related disability independent of the visual field (VF) damage and thus may provide additional patient-relevant disability information beyond what is captured by standard VF testing.

خرید پکیج و مشاهده آنلاین مقاله


Retinal Nerve Fiber Layer Thickness in Patients With Obstructive Sleep Apnea.

Devi, Thounaojam S. MD *; Agrawal, Ajai MS, FICS, MAMS *; Gupta, Neeti MS *; Gupta, Ravi MD +; Samanta, Ramanuj MS *; Nishant, Prateek MD, DNB, MBA ++

doi : 10.1097/IJG.0000000000002193

Average and superior quadrant retinal nerve fiber layer thickness (RNFLT) was lower in the more severe obstructive sleep apnea (OSA) group and inversely associated with apnea-hypopnea index (AHI).

خرید پکیج و مشاهده آنلاین مقاله


Frequency of Visual Fields Needed to Detect Glaucoma Progression: A Computer Simulation Using Linear Mixed Effects Model.

Sabouri, Samaneh MSc *; Haem, Elham PhD *; Masoumpour, Masoumeh MD +; Vermeer, Koenraad A. PhD ++; Lemij, Hans G. MD, PhD ++; Yousefi, Siamak PhD [S],[//]; Pourahmad, Saeedeh PhD *

doi : 10.1097/IJG.0000000000002155

Irregular visual field test frequency at relatively short intervals initially and longer intervals later on in the disease provided acceptable results in detecting glaucoma progression.

خرید پکیج و مشاهده آنلاین مقاله


Optic Disc Measurements in Children by Optical Coherence Tomography.

Hashemi, Hassan MD *; Khabazkhoob, Mehdi PhD +; Heydarian, Samira PhD ++; Emamian, Mohammad Hassan MD, PhD [S]; Fotouhi, Akbar MD, PhD [//]

doi : 10.1097/IJG.0000000000002159

This study showed the distribution of optic disc indices in a population-based sample of Iranian children in detail. Refractive errors and biometric components are among the ocular factors that are related to these indices.

خرید پکیج و مشاهده آنلاین مقاله


Eye Drop Adherence With an Eye Drop Bottle Cap Monitor.

Kinast, Robert M. MD *; Sanchez, Facundo G. MD *; Rees, Jack P. BA *; Yeh, Kaileen MD *; Gardiner, Stuart K. PhD *; Dawes, Jacob MS +; Johnston, Matthew L. PhD +; Porter, J. David PhD ++; Klei, Viridian *; Mansberger, Steven L. MD, MPH *

doi : 10.1097/IJG.0000000000002166

An eye drop bottle cap monitor with audio and visual alarms measured eye drop adherence in 50 subjects with glaucoma. Baseline adherence rates were too high to test if the alarms could improve adherence.

خرید پکیج و مشاهده آنلاین مقاله


Two-Year Outcomes of Trabeculectomy and Phacotrabeculectomy in Primary Open Angle Versus Primary Angle Closure Glaucoma.

Winuntamalakul, Yolradee MD *,+; Chansangpetch, Sunee MD, BPH *,+; Ratanawongphaibul, Kitiya MD *,+; Itthipanichpong, Rath MD *,+; Manassakorn, Anita MD *,+; Tantisevi, Visanee MD *,+; Rojanapongpun, Prin MD *,+

doi : 10.1097/IJG.0000000000002172

Phacotrabeculectomy had a significantly lower 24-month failure rate than the isolated trabeculectomy in both the primary open angle glaucoma (POAG) and primary angle closure glaucoma (PACG) patients.

خرید پکیج و مشاهده آنلاین مقاله


Efficacy of a Novel Zigzag Application Pattern for Micropulse Transscleral Cyclophotocoagulation for the Management of Glaucoma.

Sami, Ahmed MS *; Aboulnasr, Tarek T. MD +; El-Shahed, Ahmed F. MD *

doi : 10.1097/IJG.0000000000002095

A zigzag mode of application effectively lowered IOP in glaucoma patients at 6 months with a low incidence of complications despite the longer application time.

خرید پکیج و مشاهده آنلاین مقاله


Hemorrhagic Complications Following Trabecular Bypass Microstent Surgery in the Setting of Antithrombotic Therapy.

Shalaby, Wesam Shamseldin MD *,+; Patel, Sonali BS ++; Lam, Sophia S. BS ++; Bechay, Joseph BS ++; Zadrozny, Izabella *; Reyes, Johannie MS *; Zhang, Qiang PhD, MPH [S]; Sharpe, James MS [S]; Lee, Daniel MD *,++; Myers, Jonathan S. MD *,++; Kolomeyer, Natasha Nayak MD *,++; Razeghinejad, Reza MD *,++; Pro, Michael J. MD *,++; Moster, Marlene R. MD *,++; Garg Shukla, Aakriti MD *,++

doi : 10.1097/IJG.0000000000002173

In this retrospective study, the use of chronic antithrombotic therapy (ATT) did not increase the risk of hemorrhagic complications after trabecular bypass microstent surgery and phacoemulsification.

خرید پکیج و مشاهده آنلاین مقاله


Segmental Suture Gonioscopy-Assisted Transluminal Trabeculotomy: Comparison of Superior Versus Inferior Hemisphere Outcomes.

Waldner, Derek M. PhD, MD *; Chaban, Yuri MD +; Penny, Michael D. MD ++; Al-Ani, Abdullah PhD, MD ++; Belkin, Avner MD [S],[//]; Ahmed, Iqbal Ike K. MD +; Schlenker, Matthew B. MSc, MD +; Gooi, Patrick MD *

doi : 10.1097/IJG.0000000000002169

Analysis of efficacy, safety, and risk factors for failure of superior versus inferior 180-degree segmental gonioscopy-assisted transluminal trabeculectomy showed no significant difference between approaches, with novel risk factors for failure identified.

خرید پکیج و مشاهده آنلاین مقاله


Outcomes of Ultrasound Cyclo Plasty in Primary Angle Closure Glaucoma.

Almobarak, Faisal A. MD *,+; Alrubean, Ahmed MD *,++; Alsarhani, Waleed K. MD *,[S],[//]; Aljenaidel, Abdullah MD *; Osman, Essam A. MD *,+

doi : 10.1097/IJG.0000000000002182

Ultrasound cyclo plasty (UCP) can be useful in decreasing the intraocular pressure (IOP) and burden of antiglaucoma medications in eyes with primary angle closure glaucoma (PACG).

خرید پکیج و مشاهده آنلاین مقاله


One Year Results of the Preserflo MicroShunt Implantation for Refractory Glaucoma.

Seuthe, Anna-Maria MD; Erokhina, Mariya MD; Szurman, Peter PhD; Haus, Arno MD

doi : 10.1097/IJG.0000000000002178

The Preserflo MicroShunt is an effective method to achieve a satisfying intraocular pressure (IOP) reduction in patients with complicated forms of glaucoma.

خرید پکیج و مشاهده آنلاین مقاله


Ultrasound Cyclo Plasty in Patients with Open Angle Glaucoma and High Myopia.

Figus, Michele MD, PhD *; Palma, Alessandro MD *; Covello, Giuseppe MD *; Agnifili, Luca MD, PhD +; Posarelli, Chiara MD, PhD *

doi : 10.1097/IJG.0000000000002185

Ultrasound cyclo plasty (UCP) using high-intensity focused ultrasound is an effective and safe procedure in lowering intraocular pressure (IOP) in patients with glaucoma, even in those with high myopia.

خرید پکیج و مشاهده آنلاین مقاله


The Diagnostic Value of Optical Coherence Tomography for Detecting Glaucoma in High Myopia.

Zhang, Yan MD; Wang, Wenxing MD; Chen, Jiawei MD; Huang, Chukai MD, PhD

doi : 10.1097/IJG.0000000000002198

Glaucomatous changes in high myopia are difficult to detect due to the similarity of functional and structural alteration in both disease. Optical coherence tomography (OCT) shows relatively high diagnostic accuracy in glaucoma with high myopia (HM).

خرید پکیج و مشاهده آنلاین مقاله


Retinal Nerve Fiber Layer Thickness/Minimum Rim Width Ratio Differentiates Glaucoma From Other Optic Neuropathies.

Boussion, Francois MD *; Guindolet, Damien MD, PhD *; Deschamps, Romain MD +; Lamirel, Cedric MD, PhD *; Vignal-Clermont, Catherine MD *

doi : 10.1097/IJG.0000000000002150

Global peripapillary retinal nerve fiber layer thickness (pRNFL)/Bruch membrane opening-minimum rim width (BMO-MRW) ratio is an objective and effective parameter to separate glaucomatous optic neuropathies (GONs) from nonGONs (NGONs).

خرید پکیج و مشاهده آنلاین مقاله


Acute Necrotizing Retinopathy After Xen Gel Stent Implantation.

Lo, Wen-Jung MD, MPH *,+; Kuang, Tung-Mei MD *,+; Chen, Shih-Jen MD, PhD *,+; Hwang, De-Kuang MD, PhD *,+

doi : 10.1097/IJG.0000000000002219

We report a case of a 45-year-old woman who developed serous retinal detachment, hypotony, and retinal necrosis after Xen gel stent implantation.

خرید پکیج و مشاهده آنلاین مقاله


Letter to the Editor: Long-Term Intraocular Pressure Fluctuation is a Risk Factor for Visual Field Progression in Advanced Glaucoma.

Rao, Aparna MD, FRCS, PhD; Khan, Sardar M. MD

doi : 10.1097/IJG.0000000000002179

خرید پکیج و مشاهده آنلاین مقاله


Response to Letter to the Editor: Long-Term Intraocular Pressure Fluctuation is a Risk Factor for Visual Field Progression in Advanced Glaucoma.

Lee, Jihei Sara MD *; Park, Sungeun MD *; Seong, Gong Je MD, PhD *; Kim, Chan Yun MD, PhD *; Lee, Sang Yeop MD *,+; Choi, Wungrak MD *; Bae, Hyoung Won MD, PhD *

doi : 10.1097/IJG.0000000000002180

خرید پکیج و مشاهده آنلاین مقاله


آیا می خواهید مدیلیب را به صفحه اصلی خود اضافه کنید؟