Brandao-de-Resende, Camilo MD, PhD *; Alcantara, Liliane de Abreu Rosa de MD +; Vasconcelos-Santos, Daniel Vitor MD, PhD +; Diniz-Filho, Alberto MD, PhD +
doi : 10.1097/IJG.0000000000002200
Volume 32(5) pgs. 327-441,e38-e42 May 2023
Teleglaucoma is the future, but there is a need for clearer regulation by government agencies and medical entities, as well as for studies to further demonstrate the cost-effectiveness and safety of teleglaucoma strategies at a global scale.
Chang, Melissa M. BS *; Yang, Christopher D. BS *; Ly, Huy Q. MD +; Minckler, Donald S. MD, MS +; Lin, Ken Y. MD, PhD *,+,++
doi : 10.1097/IJG.0000000000002215
Intraoperative anterior chamber (AC) washout reduces the odds of hypertensive phase (HP) by 95% compared with those not receiving washout during Ahmed glaucoma implant (AGI), suggesting AC washout is an effective prophylaxis for postoperative HP.
Bonham, Luke W. MD *,+; Mihailovic, Aleksandra ScM *,+; Xiao, Grace BA *,+; West, Sheila K. PhD *,+; Friedman, David S. MD, PhD *,+; Ramulu, Pradeep Y. MD, PhD *,+
doi : 10.1097/IJG.0000000000002191
Optical coherence tomography (OCT) estimated retinal nerve fiber layer (RNFL) thickness associated with glaucoma-related disability independent of the visual field (VF) damage and thus may provide additional patient-relevant disability information beyond what is captured by standard VF testing.
Devi, Thounaojam S. MD *; Agrawal, Ajai MS, FICS, MAMS *; Gupta, Neeti MS *; Gupta, Ravi MD +; Samanta, Ramanuj MS *; Nishant, Prateek MD, DNB, MBA ++
doi : 10.1097/IJG.0000000000002193
Average and superior quadrant retinal nerve fiber layer thickness (RNFLT) was lower in the more severe obstructive sleep apnea (OSA) group and inversely associated with apnea-hypopnea index (AHI).
Sabouri, Samaneh MSc *; Haem, Elham PhD *; Masoumpour, Masoumeh MD +; Vermeer, Koenraad A. PhD ++; Lemij, Hans G. MD, PhD ++; Yousefi, Siamak PhD [S],[//]; Pourahmad, Saeedeh PhD *
doi : 10.1097/IJG.0000000000002155
Irregular visual field test frequency at relatively short intervals initially and longer intervals later on in the disease provided acceptable results in detecting glaucoma progression.
Hashemi, Hassan MD *; Khabazkhoob, Mehdi PhD +; Heydarian, Samira PhD ++; Emamian, Mohammad Hassan MD, PhD [S]; Fotouhi, Akbar MD, PhD [//]
doi : 10.1097/IJG.0000000000002159
This study showed the distribution of optic disc indices in a population-based sample of Iranian children in detail. Refractive errors and biometric components are among the ocular factors that are related to these indices.
Kinast, Robert M. MD *; Sanchez, Facundo G. MD *; Rees, Jack P. BA *; Yeh, Kaileen MD *; Gardiner, Stuart K. PhD *; Dawes, Jacob MS +; Johnston, Matthew L. PhD +; Porter, J. David PhD ++; Klei, Viridian *; Mansberger, Steven L. MD, MPH *
doi : 10.1097/IJG.0000000000002166
An eye drop bottle cap monitor with audio and visual alarms measured eye drop adherence in 50 subjects with glaucoma. Baseline adherence rates were too high to test if the alarms could improve adherence.
Winuntamalakul, Yolradee MD *,+; Chansangpetch, Sunee MD, BPH *,+; Ratanawongphaibul, Kitiya MD *,+; Itthipanichpong, Rath MD *,+; Manassakorn, Anita MD *,+; Tantisevi, Visanee MD *,+; Rojanapongpun, Prin MD *,+
doi : 10.1097/IJG.0000000000002172
Phacotrabeculectomy had a significantly lower 24-month failure rate than the isolated trabeculectomy in both the primary open angle glaucoma (POAG) and primary angle closure glaucoma (PACG) patients.
Sami, Ahmed MS *; Aboulnasr, Tarek T. MD +; El-Shahed, Ahmed F. MD *
doi : 10.1097/IJG.0000000000002095
A zigzag mode of application effectively lowered IOP in glaucoma patients at 6 months with a low incidence of complications despite the longer application time.
Shalaby, Wesam Shamseldin MD *,+; Patel, Sonali BS ++; Lam, Sophia S. BS ++; Bechay, Joseph BS ++; Zadrozny, Izabella *; Reyes, Johannie MS *; Zhang, Qiang PhD, MPH [S]; Sharpe, James MS [S]; Lee, Daniel MD *,++; Myers, Jonathan S. MD *,++; Kolomeyer, Natasha Nayak MD *,++; Razeghinejad, Reza MD *,++; Pro, Michael J. MD *,++; Moster, Marlene R. MD *,++; Garg Shukla, Aakriti MD *,++
doi : 10.1097/IJG.0000000000002173
In this retrospective study, the use of chronic antithrombotic therapy (ATT) did not increase the risk of hemorrhagic complications after trabecular bypass microstent surgery and phacoemulsification.
Waldner, Derek M. PhD, MD *; Chaban, Yuri MD +; Penny, Michael D. MD ++; Al-Ani, Abdullah PhD, MD ++; Belkin, Avner MD [S],[//]; Ahmed, Iqbal Ike K. MD +; Schlenker, Matthew B. MSc, MD +; Gooi, Patrick MD *
doi : 10.1097/IJG.0000000000002169
Analysis of efficacy, safety, and risk factors for failure of superior versus inferior 180-degree segmental gonioscopy-assisted transluminal trabeculectomy showed no significant difference between approaches, with novel risk factors for failure identified.
Almobarak, Faisal A. MD *,+; Alrubean, Ahmed MD *,++; Alsarhani, Waleed K. MD *,[S],[//]; Aljenaidel, Abdullah MD *; Osman, Essam A. MD *,+
doi : 10.1097/IJG.0000000000002182
Ultrasound cyclo plasty (UCP) can be useful in decreasing the intraocular pressure (IOP) and burden of antiglaucoma medications in eyes with primary angle closure glaucoma (PACG).
Seuthe, Anna-Maria MD; Erokhina, Mariya MD; Szurman, Peter PhD; Haus, Arno MD
doi : 10.1097/IJG.0000000000002178
The Preserflo MicroShunt is an effective method to achieve a satisfying intraocular pressure (IOP) reduction in patients with complicated forms of glaucoma.
Figus, Michele MD, PhD *; Palma, Alessandro MD *; Covello, Giuseppe MD *; Agnifili, Luca MD, PhD +; Posarelli, Chiara MD, PhD *
doi : 10.1097/IJG.0000000000002185
Ultrasound cyclo plasty (UCP) using high-intensity focused ultrasound is an effective and safe procedure in lowering intraocular pressure (IOP) in patients with glaucoma, even in those with high myopia.
Zhang, Yan MD; Wang, Wenxing MD; Chen, Jiawei MD; Huang, Chukai MD, PhD
doi : 10.1097/IJG.0000000000002198
Glaucomatous changes in high myopia are difficult to detect due to the similarity of functional and structural alteration in both disease. Optical coherence tomography (OCT) shows relatively high diagnostic accuracy in glaucoma with high myopia (HM).
Boussion, Francois MD *; Guindolet, Damien MD, PhD *; Deschamps, Romain MD +; Lamirel, Cedric MD, PhD *; Vignal-Clermont, Catherine MD *
doi : 10.1097/IJG.0000000000002150
Global peripapillary retinal nerve fiber layer thickness (pRNFL)/Bruch membrane opening-minimum rim width (BMO-MRW) ratio is an objective and effective parameter to separate glaucomatous optic neuropathies (GONs) from nonGONs (NGONs).
Lo, Wen-Jung MD, MPH *,+; Kuang, Tung-Mei MD *,+; Chen, Shih-Jen MD, PhD *,+; Hwang, De-Kuang MD, PhD *,+
doi : 10.1097/IJG.0000000000002219
We report a case of a 45-year-old woman who developed serous retinal detachment, hypotony, and retinal necrosis after Xen gel stent implantation.
Rao, Aparna MD, FRCS, PhD; Khan, Sardar M. MD
Lee, Jihei Sara MD *; Park, Sungeun MD *; Seong, Gong Je MD, PhD *; Kim, Chan Yun MD, PhD *; Lee, Sang Yeop MD *,+; Choi, Wungrak MD *; Bae, Hyoung Won MD, PhD *
آیا می خواهید مدیلیب را به صفحه اصلی خود اضافه کنید؟